Acetic Acid micro flowmeter
email: porter@microflowmeter.com Shanghai JSN Micro Flow MeterCO.,LTD has struggled in the wave of market economy. The development has beenfor decades, with high popularity and good reputation. The main products:supermicro flow meter, fuel consumptionflow meter,spur gear flow meter,gear pump,gear metering pump etc. Withits excellent price/performance ratio favored by users, we have a conscientiousworking attitude, a solid business foundation, a strong sense of solidarity andcooperation, and a professional and technical staff. We take the quality,reputation, and perfect after-sales service as the guideline, with highquality. The products, strong technical force, advanced testing methods serveour customers.

Acetic Acid micro flowmeter
Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.
TheCX-M and G-series mirco flow meters are the world"s new volumetric flowmetersintroduced by BASF in 2011. Since its establishment, the CX-M oval gear flowmeter and the G-series mirco flow meters have been selling well in the marketfor more than 100,000 units a year since they were sold. The third generationlaunched in 2017, with more than 90% accuracy and stability, won thecertification of the National Bureau of Metrology. The quality and reliabilityof Shanghai JiShen instruments need not worry. According to the statistics ofChina Instrument Association, Deep flow meter reliability has always beenranked in the top 3, especially in the long-term statistics failure rate is farbelow the industry average, deep advocate "the best after-sales service isno service", but also achieved a continuous three years without qualitycomplaints .

Acetic Acid micro flowmeter
shell is formed by an oval gear rotor. The gearrotor meshes with the rotating shaft to convey the fluid. The permanent magnetarranged in the rotor is used for the detection of the rotor rotation. Twosensor holes are placed on the upper end to cover the detection sensor. Asealing ring is installed between the housing and the upper and lower end capsto prevent leakage of the measurement fluid. The base depth flowmeter is madeof a material with high wear resistance so that the flowmeter Can guaranteehigh precision measurement within the long service life.

Acetic Acid micro flowmeter
Technicaldata of Gear type flow meter
Model | K-factor | Minimum flow | Flow range | Accuracy |
G0.025 | 0.025ml | 0.001L/Min | 0.008~2L/Min | 0.5% |
G0.04 | 0.04ml | 0.004L/Min | 0.2~4 L/min | 0.5% |
G0.1 | 0.4ml | 0.008L/Min | 0.01~8L/min | 0.5% |
G0.2 | 0.245ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G0.4 | 0.4ml | 0.01L/Min | 0.16~16 L/min | 0.5% |
G1 | 1.036ml | 0.02L/Min | 0.4~80 L/min | 0.5% |
What are the precautions for the gear flow meter?
1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.
2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted
3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.